Fire Alarm Routing Equipment are subject to mandatory BIS ISI certification under the Fire Detection and Alarm Systems (Quality Control) Order, 2026. From 6 mo after publication of the QCO in the e-Gazette, these products cannot be lawfully manufactured for sale, imported, or distributed in India without a valid BIS ISI licence under IS/ISO 7240-21:2005. Non-compliance attracts penalties under the BIS Act, 2016 — product seizure, fines, and prosecution.

This guide covers the applicable Indian Standard, key technical and safety requirements, the step-by-step certification process, documentary requirements, and the most common compliance pitfalls for manufacturers and importers.

📜 Applicable Indian Standard

📌 Routing equipment relays fire-alarm signals to control rooms, fire-service stations, and remote monitoring centres. The QCO ensures signal-path redundancy, transmission reliability, and fault reporting — critical for emergency response.

🔬 Key Quality Requirements Under IS/ISO 7240-21:2005

BIS-approved laboratories evaluate the following during type testing:

Signal-Path Reliability

Primary and backup signal-path performance. Loss-of-communication fault detection and reporting per ISO 7240-21.

Transmission Performance

Telephone-line, cellular, or IP transmission performance under standard conditions. Signal-acknowledgement testing.

Power & Backup

Primary mains operation, battery backup duration, charger performance, and supply-fault reporting.

Marking & Documentation

Transmission-path types supported, backup duration, alarm protocols, and ISI Mark plus licence number on the housing.

Products covered under IS/ISO 7240-21:2005:

📋 Step-by-Step BIS ISI Certification Process

  1. Transmission-Path IdentificationIdentify supported transmission paths — telephone, cellular, IP — and backup configurations. Test reports must cover each path.
  2. Application FilingSubmit online application on manak.bis.gov.in. Indian manufacturers via Product Certification Scheme; foreign manufacturers via FMCS with appointed AIR.
  3. Sample TestingSubmit complete routing equipment to a BIS-recognised fire-detection testing laboratory. Transmission, redundancy, and EMC tests: approximately 4–6 weeks.
  4. Factory InspectionBIS officers inspect electronics manufacturing, programming station, and in-house testing capability.
  5. Licence GrantBIS issues the ISI Mark licence. ISI Mark plus licence number is applied on the equipment housing and packaging.
  6. Surveillance & RenewalPeriodic BIS market sample testing, factory audits, and annual marking fees keep the licence active.

📄 Documents Required

6 moQCO Enforcement
4–6 wksLab Testing Time
3–6 moFull Process
Redundancy Tested: Routing equipment must demonstrate signal-path redundancy and reliability. A single failure mode in transmission can disqualify the model from BIS testing.

Common Compliance Pitfalls

Common issues include signal-path failure under simulated outage, backup battery shortfall, transmission delay beyond ISO limits, and incomplete protocol documentation.