CDSCO · Class C Medical Device

CDSCO Licence for Guidewires in India

Class C licensing for intravascular guidewires — ISO 11070, sterility and biocompatibility, documents, fees, timeline and routes.

Published: September 2026 Reading Time: 13 min

A guidewire is the thin, steerable wire that leads catheters and devices to the right place inside the vascular system — small, but its performance directly affects the safety of every interventional procedure it enables. Because it enters the circulatory system, CDSCO regulates the guidewire as a Class C device with the intravascular-accessory standard, sterility and biocompatibility behind the licence. This guide covers the full CDSCO pathway for guidewires under the Medical Devices Rules, 2017 — classification, licence route, ISO 11070, the documents, the fees and the timeline.

📌 Under the Medical Devices Rules, 2017, Guidewires are a notified medical device and cannot be manufactured, imported or sold in India without a CDSCO licence. As a Class C device (moderate-to-high risk), a domestic manufacturer applies in Form MD-7 to the Central Licensing Authority (CDSCO headquarters) and receives the licence in Form MD-9; an importer applies in Form MD-14 through an Indian Authorised Agent and receives an import licence in Form MD-15 from the Central Licensing Authority. The licence must be in hand before the product is made or the first consignment lands.

📋 Is a CDSCO Licence Mandatory for Guidewires?

Yes. A guidewire is a notified Class C medical device and cannot be manufactured, imported or sold in India without a CDSCO licence. Because it is Class C, a domestic manufacturer applies to the Central Licensing Authority in Form MD-7 for a Form MD-9 licence; an importer applies in Form MD-14 for a Form MD-15 import licence. Diagnostic and interventional guidewires, coated and uncoated, are covered, with each type and size declared.

🧭 Risk Classification of Guidewires

Every medical device in India is placed in one of four risk classes under the First Schedule of the Medical Devices Rules, 2017. The class is the single most important decision in the whole application — it fixes which authority you file with, which form you use, the fee, the audit route and the timeline.

Class ALow risk
Class BLow-moderate
Class CModerate-high
Class DHigh risk

Guidewires are classified as Class C. A guidewire is a surgically invasive device that connects to the central circulatory system for short-term use, placing it in Class C (moderate-to-high risk) under the First Schedule. Classification follows the CDSCO classification list for the relevant medical-device category read with the First Schedule rules; where a device could fall in two classes, the higher class applies, and an accessory is classified in its own right.

🪪 Which CDSCO Licence You Need for Guidewires

There are two distinct routes, and which one applies depends on whether you make the device in India or bring it in from overseas:

📘 Applicable Standards for Guidewires

Guidewires are evaluated against the intravascular-accessory standard plus sterility and biocompatibility:

🗂️ The Core Technical Dossier — Required for Every Application

Whether you file for a manufacturing licence or an import licence, CDSCO expects the same backbone of technical evidence built around the device. Getting this base right is what decides whether the file clears in one review cycle or comes back as a deficiency letter; the device-specific documents in the next section sit on top of it.

➕ Device-Specific Documents for Guidewires

On top of the core dossier, a guidewire file should carry:

For an import licence (Form MD-14) there are three further essentials on top of the dossier above:

🏭 QMS & Essential Principles — What CDSCO Checks

The Medical Devices Rules, 2017 are built on two pillars, and both are assessed for guidewires:

🏷️ Guidewires Label & IFU Requirements

Guidewire labelling is checked for size, sterility and single-use messaging:

⚖️ Coated vs Uncoated, and the Particulate Question

Guidewires split into uncoated and coated (PTFE, silicone or hydrophilic) types. Coatings improve trackability but introduce their own risks — coating integrity and particulate shedding are recognised safety concerns and draw specific evidence requirements. Decide which guidewire types, sizes and coatings you are registering, and evidence coating integrity for coated wires. A coating claim without integrity/particulate data is a common cause of queries.

🛠️ Step-by-Step Registration Process

  1. Confirm the classificationFix the risk class against the CDSCO classification list and the First Schedule — this decides the form, the authority, the fee and the audit route before anything else is drafted.
  2. Choose the routeManufacturing (Form MD-3 / MD-7) or import (Form MD-14). Importers appoint an Indian Authorised Agent holding a valid manufacturing or wholesale licence.
  3. Build the Device Master File and Plant Master FileAssemble device description, materials, design and process data, ISO 14971 risk file, sterilisation and stability data, and the site file with the QMS.
  4. Complete the Essential Principles checklistMap the device against each applicable essential principle and cite the BIS/IS or ISO/IEC standard or test report relied on for each.
  5. Draw the test and performance reportsTest to the applicable standards at an accredited laboratory; sterile and measuring devices carry additional validation.
  6. Register and file on the CDSCO Online (SUGAM) portalCreate the account, pay the government fee online and upload the full dossier under the correct form.
  7. Site audit / inspectionNotified-Body audit for Class A/B manufacture; CDSCO joint-team inspection for Class C/D and, where ordered, for overseas sites on import.
  8. Respond to queries and receive the licenceAnswer the deficiency letter within the stipulated period; on approval the licence issues in Form MD-5 / MD-9 (manufacture) or MD-15 (import).

💰 Government Fees

Fees are set in the Second Schedule of the Medical Devices Rules and paid online through the CDSCO portal. They differ sharply by route and class:

Manufacture — Class C (Form MD-9)

Rs 50,000 per site plus Rs 1,000 for each distinct device, to the Central Licensing Authority (CDSCO headquarters).

Import (Form MD-15)

Charged per site and per device and paid in USD; for a Class C device it is among the higher import slabs, so budget by the number of sites and distinct devices.

Test licence (Form MD-13)

A modest fee for importing or making a small quantity for testing, evaluation, demonstration or clinical investigation.

Retention

Licences do not expire, but a retention fee equal to the licence fee is payable every five years to keep the licence alive.

Import fees under Form MD-15 run from roughly USD 1,000 per site plus USD 50 per device for lower-risk devices to about USD 3,000 per site plus USD 1,500 per device for Class C and D. Always confirm the current figure on the CDSCO portal before you file, as the schedule is revised from time to time.

⏱️ Timeline & Validity at a Glance

6-9 monthsManufacture (Form MD-9)
6-9 monthsImport (Form MD-15)
PerpetualLicence Validity
5 yearsRetention Fee Cycle

The single biggest lever on timeline is the quality of the first submission: every deficiency letter effectively restarts the clock, so a dossier that pre-empts the common objections is worth far more than one filed quickly and corrected later. Unlike the old registration certificates, an MDR 2017 licence does not carry an expiry date — it stays valid as long as the retention fee is paid every five years and the conditions of licence are met.

⚠️ Where Guidewires Applications Get Queried

Class C blood-contacting devices draw detailed queries. The recurring reasons are:

🔗 Related Approvals Alongside CDSCO

A CDSCO device licence rarely travels alone. Depending on the device and the business, plan for these adjacent approvals in parallel, because any one of them can hold a consignment at the port or stop a sale even when the CDSCO licence is in order:

✅ Post-Approval Obligations

The licence is the start of an ongoing compliance duty, not the end of it. After grant, the licensee must:

Confirm the current position before you file: This guide reflects the Medical Devices Rules, 2017 and CDSCO guidance as published and is current as at 2026. Forms, fees, classification and standards are revised from time to time — verify the applicable class, standard and fee on the CDSCO portal, or with us, before drawing test reports or filing.

❓ Frequently Asked Questions

What CDSCO class is a guidewire?

A guidewire is Class C, so a domestic manufacturer files Form MD-7 for an MD-9 licence with the Central Licensing Authority, and an importer files Form MD-14 for an MD-15 licence.

Which standard applies to guidewires in India?

ISO 11070 for sterile single-use intravascular guidewires (and related introducers), with ISO 10993 haemocompatibility and validated sterilisation.

Do coated guidewires need extra evidence?

Yes — coating integrity and particulate-release data are expected for coated (e.g. hydrophilic) guidewires, on top of the general ISO 11070 requirements.

Is a site inspection required?

Yes — for Class C manufacture, a CDSCO joint audit team inspects the site before the MD-9 licence is granted.

How long does guidewire registration take?

Budget roughly six to nine months for a complete Class C manufacturing (MD-9) or import (MD-15) file.

Does the licence expire?

No — the MDR 2017 licence is perpetual, subject to the five-yearly retention fee and continued compliance.

Guidewires — CDSCO Licensing Handled End to End

Global Approbation manages the complete CDSCO medical-device process for guidewires — classification, standard mapping, Device and Plant Master File preparation, ISO 13485 and Essential Principles readiness, SUGAM filing, audit support and query response — so your licence issues without avoidable delay.

Talk to Our CDSCO Team Global Market Access