CDSCO · Class B Medical Device

CDSCO Licence for ECG Machines in India

Class B licensing for electrocardiographs — IEC 60601-2-25, IEC 60601 electrical safety and EMC, documents, fees, timeline and routes.

Published: September 2026 Reading Time: 13 min

An electrocardiograph (ECG/EKG machine) records the heart's electrical activity, and clinicians make diagnostic and treatment decisions on its traces. Because it is a diagnostic electro-medical device connected to the patient, CDSCO regulates the ECG machine as a Class B device with the electrocardiograph particular standard and the general electro-medical safety framework behind the licence. This guide covers the full CDSCO pathway for ECG machines under the Medical Devices Rules, 2017 — classification, licence route, IEC 60601-2-25, the documents, the fees and the timeline.

📌 Under the Medical Devices Rules, 2017, ECG Machines are a notified medical device and cannot be manufactured, imported or sold in India without a CDSCO licence. As a Class B device (low-to-moderate risk), a domestic manufacturer applies in Form MD-3 to the State Licensing Authority (SLA) and receives the licence in Form MD-5; an importer applies in Form MD-14 through an Indian Authorised Agent and receives an import licence in Form MD-15 from the Central Licensing Authority. The licence must be in hand before the product is made or the first consignment lands.

📋 Is a CDSCO Licence Mandatory for ECG Machines?

Yes. An ECG machine is a notified Class B medical device and cannot be manufactured, imported or sold in India without a CDSCO licence. A domestic manufacturer holds a Form MD-5 licence from the State Licensing Authority; an importer holds a Form MD-15 import licence through an Indian Authorised Agent. Resting, stress, Holter and multi-channel ECG systems fall within the framework.

🧭 Risk Classification of ECG Machines

Every medical device in India is placed in one of four risk classes under the First Schedule of the Medical Devices Rules, 2017. The class is the single most important decision in the whole application — it fixes which authority you file with, which form you use, the fee, the audit route and the timeline.

Class ALow risk
Class BLow-moderate
Class CModerate-high
Class DHigh risk

ECG Machines are classified as Class B. An ECG machine is an active diagnostic device connected to the patient whose output informs clinical decisions, placing it in Class B under the First Schedule. Classification follows the CDSCO classification list for the relevant medical-device category read with the First Schedule rules; where a device could fall in two classes, the higher class applies, and an accessory is classified in its own right.

🪪 Which CDSCO Licence You Need for ECG Machines

There are two distinct routes, and which one applies depends on whether you make the device in India or bring it in from overseas:

📘 Applicable Standards for ECG Machines

ECG machines are evaluated against the electrocardiograph particular standard plus the electro-medical framework:

🗂️ The Core Technical Dossier — Required for Every Application

Whether you file for a manufacturing licence or an import licence, CDSCO expects the same backbone of technical evidence built around the device. Getting this base right is what decides whether the file clears in one review cycle or comes back as a deficiency letter; the device-specific documents in the next section sit on top of it.

Device-Specific Documents for ECG Machines

On top of the core dossier, an ECG-machine file should carry:

For an import licence (Form MD-14) there are three further essentials on top of the dossier above:

🏭 QMS & Essential Principles — What CDSCO Checks

The Medical Devices Rules, 2017 are built on two pillars, and both are assessed for ecg machines:

🏷️ ECG Machines Label & IFU Requirements

ECG-machine labelling and the IFU are checked for safety and connection information:

⚖️ Diagnostic ECG vs Monitor vs Consumer Wearable

Three products get mixed up here. A diagnostic electrocardiograph follows IEC 60601-2-25; a patient monitor's ECG function follows IEC 60601-2-27; and a consumer wearable that records a single-lead ECG is still a medical device if it makes a health claim, but with its own considerations. Interpretation/measurement software raises the evidence bar further. Fix which device and which claims you are registering before drawing test reports, so the right particular standard is cited.

🛠️ Step-by-Step Registration Process

  1. Confirm the classificationFix the risk class against the CDSCO classification list and the First Schedule — this decides the form, the authority, the fee and the audit route before anything else is drafted.
  2. Choose the routeManufacturing (Form MD-3 / MD-7) or import (Form MD-14). Importers appoint an Indian Authorised Agent holding a valid manufacturing or wholesale licence.
  3. Build the Device Master File and Plant Master FileAssemble device description, materials, design and process data, ISO 14971 risk file, sterilisation and stability data, and the site file with the QMS.
  4. Complete the Essential Principles checklistMap the device against each applicable essential principle and cite the BIS/IS or ISO/IEC standard or test report relied on for each.
  5. Draw the test and performance reportsTest to the applicable standards at an accredited laboratory; sterile and measuring devices carry additional validation.
  6. Register and file on the CDSCO Online (SUGAM) portalCreate the account, pay the government fee online and upload the full dossier under the correct form.
  7. Site audit / inspectionNotified-Body audit for Class A/B manufacture; CDSCO joint-team inspection for Class C/D and, where ordered, for overseas sites on import.
  8. Respond to queries and receive the licenceAnswer the deficiency letter within the stipulated period; on approval the licence issues in Form MD-5 / MD-9 (manufacture) or MD-15 (import).

💰 Government Fees

Fees are set in the Second Schedule of the Medical Devices Rules and paid online through the CDSCO portal. They differ sharply by route and class:

Manufacture — Class B (Form MD-5)

Rs 5,000 per site plus Rs 500 for each distinct device, to the State Licensing Authority (SLA).

Import (Form MD-15)

Charged per site and per device and paid in USD; for a Class B device it is among the higher import slabs, so budget by the number of sites and distinct devices.

Test licence (Form MD-13)

A modest fee for importing or making a small quantity for testing, evaluation, demonstration or clinical investigation.

Retention

Licences do not expire, but a retention fee equal to the licence fee is payable every five years to keep the licence alive.

Import fees under Form MD-15 run from roughly USD 1,000 per site plus USD 50 per device for lower-risk devices to about USD 3,000 per site plus USD 1,500 per device for Class C and D. Always confirm the current figure on the CDSCO portal before you file, as the schedule is revised from time to time.

⏱️ Timeline & Validity at a Glance

3-6 monthsManufacture (Form MD-5)
6-9 monthsImport (Form MD-15)
PerpetualLicence Validity
5 yearsRetention Fee Cycle

The single biggest lever on timeline is the quality of the first submission: every deficiency letter effectively restarts the clock, so a dossier that pre-empts the common objections is worth far more than one filed quickly and corrected later. Unlike the old registration certificates, an MDR 2017 licence does not carry an expiry date — it stays valid as long as the retention fee is paid every five years and the conditions of licence are met.

⚠️ Where ECG Machines Applications Get Queried

Common query reasons for ECG-machine applications are:

🔗 Related Approvals Alongside CDSCO

A CDSCO device licence rarely travels alone. Depending on the device and the business, plan for these adjacent approvals in parallel, because any one of them can hold a consignment at the port or stop a sale even when the CDSCO licence is in order:

Post-Approval Obligations

The licence is the start of an ongoing compliance duty, not the end of it. After grant, the licensee must:

Confirm the current position before you file: This guide reflects the Medical Devices Rules, 2017 and CDSCO guidance as published and is current as at 2026. Forms, fees, classification and standards are revised from time to time — verify the applicable class, standard and fee on the CDSCO portal, or with us, before drawing test reports or filing.

Frequently Asked Questions

What CDSCO class is an ECG machine?

An electrocardiograph is Class B. A domestic manufacturer files Form MD-3 for an MD-5 licence from the State Licensing Authority; an importer files Form MD-14 for an MD-15 licence.

Which standard applies to ECG machines in India?

IEC 60601-2-25 for electrocardiographs (or IEC 60601-2-27 for ECG monitoring), with IEC 60601-1 electrical safety and IEC 60601-1-2 EMC.

Is a factory audit required?

Yes — for Class B manufacture a CDSCO-empanelled Notified Body audits the site before the MD-5 licence is granted.

Does ECG interpretation software need extra evidence?

Yes — where the device measures or interprets the ECG, the software lifecycle and verification/validation documentation are assessed.

How long does registration take?

A complete Class B manufacturing (MD-5) file is usually cleared in about three to six months; an import (MD-15) file typically takes six to nine months.

Does the licence expire?

No — the MDR 2017 licence is perpetual, subject to the five-yearly retention fee and continued compliance.

ECG Machines — CDSCO Licensing Handled End to End

Global Approbation manages the complete CDSCO medical-device process for ecg machines — classification, standard mapping, Device and Plant Master File preparation, ISO 13485 and Essential Principles readiness, SUGAM filing, audit support and query response — so your licence issues without avoidable delay.

Talk to Our CDSCO Team Global Market Access